Information

Common terms for ultraviolet disinfection
Time:25.04.2021Reading times:693

Ultraviolet (UV) is a kind of electromagnetic wave whose wavelength is between 100nm and 380nm. The ultraviolet wave band with disinfection ability is between 200nm and 280nm. 

After ultraviolet disinfection of ultraviolet disinfection, the ultraviolet energy absorbed by the pathogenic microorganism at 200nm ~ 280nm, the mutation of its genetic material (nucleic acid) causes the cell not to divide and multiply any more. 


UV INTENSITY UV INTENSITY UV energy received per unit area of time perpendicular to the direction of UV propagation. In this standard, UV intensity is used to describe the UV energy of UV disinfection equipment. Unit Common mW/cm2.

UV TRANSMITTANCE UV transmittance (UVT) the ratio of the UNABSORBED UV rays to the total UV output at 253.7 nm. UV dose the amount of UV energy received per unit area of UV dose, usually in millijoule per square centimeter (mJ/cm2) or focal per square meter (j/m2) .

Device UV average dose reactor average dose, or AD, reduces the UV lamp to a point source, then calculates the average UV intensity in the sterilizer using the point source cumulation method, multiplied by the average exposure time to get the dose.
The average dose is the theoretical dose of ultraviolet disinfection equipment, which is usually calculated by UVDis calculation software, so it is sometimes called UVDis dose.

The effective dose of ultraviolet (UV) of equipment is the microbial inactivation UV dose that can be achieved by ED UV disinfection equipment, or the biological test dose of UV disinfection equipment, collectively referred to as the effective UV dose of equipment.

UV Dose Response Curve (UV Dose Response Curve) reflects the relationship between the inactivation or disinfection of a microorganism and the UV dose received. Inactivation is usually expressed as log10(n) or log10(n/n 0) , where n 0 is the pre-uv microbial content and n is the post-uv microbial content.

LOW PRESSURE LAMP FLUORESCENT LAMP operates under internal pressure from 0.13 PA to 1.33 PA with an input power of about 0.5 w/cm arc length and an output power of about 0.2 w/cm arc length under bactericidal UV, the BACTERICIDAL UV can be output at 253.7 nm. Low pressure high output lamp fluorescent lamp operates under internal pressure from 0.13 PA to 1.33 PA with an input power of about 1.5 w/cm arc length and a bactericidal UV output power of about 0.6 W/CM ARC length, the BACTERICIDAL UV can be output at 253.7 nm.

Medium Pressure Lamp Medium Pressure Mercury Vapor Lamp operates under internal pressure from 0.013 MPA to 1.330 MPA, the input power is about 50w to 150W/cm arc length, and the output power of bactericidal ultraviolet energy is about 7.5 w to 23W/cm arc length, the GERMICIDAL UV can output multi-frequency spectrum in 200nm ~ 280nm GERMICIDAL band.

NEW UV lamp new ultraviolet lamp 100 hours of initial operation after a stable break-in of the UV lamp. UV Lamp Aging Factor CLH lamp aging factor ratio of the UV output power at the end of the lifetime of the UV lamp to the UV output power of the new UV lamp. Scaling Factor CJG lamp fouling factor ratio of the UV transmittance of the UV lamp sleeve in use to the UV transmittance of the clean UV lamp sleeve.

UV Lamp Operating Life Operation Life of UV lamp effective output continuous or cumulative operating time. UV STERILIZER UV disinfector can be used to irradiate cavities and containers.

The ultraviolet sterilizer consists of ultraviolet lamp, quartz sleeve, ballast, ultraviolet intensity sensor, cleaning system and other parts sealed in the container.

UV MODULES UV modules to open channel as the UV irradiation cavity. The ultraviolet lamp module group is composed of ultraviolet lamp, quartz sleeve, ballast, ultraviolet intensity sensor, cleaning system and so on. UV disinfection equipment validation of UV disinfection equipment actual disinfection performance, UV effective dose, UV Lamp Aging Coefficient, UV Lamp Casing Scaling Coefficient of the relevant experiments to verify.